Download e-book for kindle: Ieee Std c57.129-1999 (Ieee Standard General Requirements by

ISBN-10: 1605669822

ISBN-13: 9781605669823

Show description

Read or Download Ieee Std c57.129-1999 (Ieee Standard General Requirements And Test Code For Oil-Immersed Hvdc Converter Transformers) PDF

Similar technique books

Agent-Oriented Software Engineering VII: 7th International by Scott A. DeLoach, Jorge L. Valenzuela (auth.), Lin Padgham, PDF

Software program architectures that include many dynamically interacting elements, each one with their very own thread of regulate, and fascinating in complicated coordination protocols, are tricky to properly and successfully engineer. Agent-oriented modelling concepts are very important for assisting the layout and improvement of such functions.

Ruth Chambers, Anthony Schwartz, Elizabeth Boath's Beating Stress in the NHS PDF

All strain isn't damaging. a specific amount of strain can improve functionality. yet over the top, unrelenting destructive strain ends up in contributors experiencing pressure. This ebook makes a speciality of the why, whilst and the way rigidity happens from operating within the overall healthiness carrier, and on a good idea ways to take, from the views of the practitioner, the office workforce, and future health care association.

Download PDF by Gerhard Schweitzer (auth.), Eric H. Maslen, Gerhard: Magnetic Bearings: Theory, Design, and Application to

Compiling the services of 9 pioneers of the sphere, Magnetic Bearings - conception, layout, and alertness to Rotating equipment bargains an encyclopedic research of this quickly rising box with a balanced combination of industrial and educational views. each section of the expertise is tested intimately, starting on the part point and continuing via an intensive exposition of the layout and function of those structures.

Additional info for Ieee Std c57.129-1999 (Ieee Standard General Requirements And Test Code For Oil-Immersed Hvdc Converter Transformers)

Example text

Three current measurements should be taken at each frequency. A typical curve of loss vs. 2. For each harmonic frequency h the value of the loss adjustment factor (multiplier) Fh is calculated by taking the ratio of loss at the harmonic frequencies compared to the fundamental frequency loss. 2—Load loss vs. 3 Measurement of three-phase converter transformers (The following information is based on material presented in Ram et al. 2 for single-phase transformers, except that a three-phase oscillator, three-phase variable transformer, and three separate amplifiers are required.

This should be the winding of hottest temperature determined from the temperature-rise-type test. If required, the winding temperature may be corrected for the additional core loss and, if appropriate, tertiary loss added to the measured winding. ” The corrected winding temperature (average and hot spot) shall not be higher than those defined and agreed to by the purchaser and manufacturer. If the transformer has an overload rating specified, the test should be performed considering the characteristics of the maximum summer time-ambient overload specified.

3, July 1988, pp. 1059–1066. [B8] The IEEE Standard Dictionary of Electrical and Electronics Terms, Sixth Edition. 9CIGRÉ publications are available from CIGRÉ Central Office, 3-5 rue de Metz, F-75015 Paris, France. Copyright © 2000 IEEE. All rights reserved.